Differential Pressure Gauge GEMTECH Wholesalers From KUMHAR MANDI Ambala – 133001 Haryana
Series G2000, GEMTECH Differential Pressure Gauges are Widely Utilized For Measuring Pressure of Fan And Blowing Machine, resistance of filter, wind speed, furnace pressure, differential pressure of pore plate, the pressure of drum water level, Liquid Amplifier And Hydraulic Pressure System. Meantime, They Are Used To Control The Automatic Valve And Specific Value Of Air-Producer Gas In Combustion And They Are Used To Test Blood Pressure And Respiratory Pressure In Medical Health Care Equipment. There Are More Than 81 Models To Suit Your Needs Precisely. The Key Components Adopt Import Materi
SPECIFICATION
- Ambient Temperature – -21 ~140 -6 ~60
- Rated Pressure -20 inHg~30 inHg (-68~103KPa)
- Overpressure – Protective rubber stopper will be blown out if rated pressure is up to about 50.8 inHg (172KPa).
- Process Connections – 1/8″ female NPT duplicate high and low pressure taps – one pair side and one pair back
- Housing – Die cast aluminum case and bezel, with acrylic cover, Exterior finish is coated gray to withstand 168 Hour Salt Spray Corrosion Test
- Accuracy – ±2% of full span at 70???(21??????(±3% on -0, and ±4% on -00)
- Range -20 inHg~38 inHg (-68KPa~130KPa)(Special Specification also can be ordered.)
FEATURES
- OEM/ODM
- There Is No Need To Fill Liquid To Gauge.
- The Gauge Can Measure Positive Pressure, Negative Pressure And Differential Pressure.
- It Will Be Easy To Install And Measure In Different Ways Because Of Two Groups Of Ports Which Can Measure Positive And Negative Pressure.
- To Eliminate The Friction From The Movement Of Gear Wheel By The Mechanism Of Magnetic Magnet Feed.
- Exact And Stable Fixed Position Of Needle.
- The Gauge Has Great Antiknock Characteristics.
- There Are 81 Types Of Ranges. Minimum is 0-60 Pa And Maximum is 0-21-KPa.
PRODUCT APPLICATIONS
- Filter Monitoring
- Air Velocity With Pitot Tube
- Blower Vacuum Monitoring
- Fan Pressure Indication
- Duct, Room or Building Pressures
- Clean Room Positive Pressure Indication
MODELS & ORDERING
GEMTECH By Model Number Popularity
Model | Description |
---|---|
G2000-0 | Differential Pressure Gage, Range 0-0.50″ w.c., minor divisions .01, calibrated for vertical scale position. |
G2000-0-SP | Differential Pressure Gage, Range 0-0.50″ w.c., with set point indicator. |
G2000-00 | Differential Pressure Gage, Range 0-0.25″ w.c., minor divisions .005, calibrated for vertical scale position. |
G2000-00AV | Differential Pressure Gage, Range 0-0.25″ w.c., velocity 300-2000 FPM, calibrated for vertical scale position. |
G2000-00N | Differential Pressure Gage, Range .05-0-.2″ w.c., minor divisions .005, calibrated for vertical scale position. |
G2000-0AV | Differential Pressure Gage, Range 0-0.50″ w.c., velocity 500-2800 FPM, calibrated for vertical scale position. |
G2000-0D | Differential Pressure Gage, Range 0-0.5″ w.c. & 0-125 Pa. |
G2000-1.5KPA | Differential Pressure Gage, Range 0-1.5 kPa, minor divisions .05. |
G2000-100CM | Differential Pressure Gage, Range 0-100 cm w.c., minor divisions 2.0. |
G2000-100MM | Differential Pressure Gage, Range 0-100 mm w.c., minor divisions 2.0. |
G2000-100PA | Differential Pressure Gage, Range 0-100 Pa, minor divisions 2.0, calibrated for vertical scale position. |
G2000-10KPA | Differential Pressure Gage, Range 0-10 kPa, minor divisions .20. |
G2000-10MM | Differential Pressure Gage, Range 0-10 mm w.c., minor divisions .20, calibrated for vertical scale position. |
G2000-125PA | Differential Pressure Gage, Range 0-125 Pa, minor divisions 5.0, calibrated for vertical scale position. |
G2000-150CM | Differential Pressure Gage, Range 0-150 cm w.c., minor divisions 5.0. |
G2000-150MM | Differential Pressure Gage, Range 0-150 mm w.c. |
G2000-15CM | Differential Pressure Gage, Range 0-15 cm w.c., minor divisions .50. |
G2000-15KPA | Differential Pressure Gage, Range 0-15 kPa, minor divisions .50. |
G2000-15MM | Differential Pressure Gage, Range 0-15 mm w.c. |
G2000-1KPA | Differential Pressure Gage, Range 0-1 kPa, minor divisions .02. |
G2000-200CM | Differential Pressure Gage, Range 0-200 cm w.c., minor divisions 5.0. |
G2000-200MM | Differential Pressure Gage, Range 0-200 mm w.c. |
G2000-20CM | Differential Pressure Gage, Range 0-20 cm w.c., minor divisions .50. |
G2000-20KPA | Differential Pressure Gage, Range 0-20 kPa, minor divisions .50. |
G2000-250CM | Differential Pressure Gage, Range 0-250 cm w.c., minor divisions 5.0. |
G2000-250MM | Differential Pressure Gage, Range 0-250 mm w.c. |
G2000-250PA | Differential Pressure Gage, Range 0-250 Pa, minor divisions 5.0. |
G2000-25CM | Differential Pressure Gage, Range 0-25 cm w.c., minor divisions .50. |
G2000-25KPA | Differential Pressure Gage, Range 0-25 kPa, minor divisions .50. |
G2000-25MM | Differential Pressure Gage, Range 0-25 mm w.c., minor divisions .50. |
G2000-2KPA | Differential Pressure Gage, Range 0-2 kPa, minor divisions .05. |
G2000-300CM | Differential Pressure Gage, Range 0-300 cm w.c., minor divisions 10.0. |
G2000-300MM | Differential Pressure Gage, Range 0-300 mm w.c. |
G2000-300PA | Differential Pressure Gage, Range 0-300 Pa, minor divisions 10.0. |
G2000-30KPA | Differential Pressure Gage, Range 0-30 kPa, minor divisions 1.0. |
G2000-30PA | Differential Pressure Gage, Range 0-30 Pa, minor divisions 1.0, calibrated for vertical scale position. |
G2000-3KPA | Differential Pressure Gage, Range 0-3 kPa, minor divisions .10. |
G2000-4KPA | Differential Pressure Gage, Range 0-4 kPa, minor divisions .10. |
G2000-500PA | Differential Pressure Gage, Range 0-500 Pa, minor divisions 10.0. |
G2000-50CM | Differential Pressure Gage, Range 0-50 cm w.c., minor divisions 1.0. |
G2000-50MM | Differential Pressure Gage, Range 0-50 mm w.c., minor divisions 1.0. |
G2000-5KPA | Differential Pressure Gage, Range 0-5 kPa, minor divisions .10. |
G2000-60PA | Differential Pressure Gage, Range 0-60 Pa, minor divisions 1.0, calibrated for vertical scale position. |
G2000-6MM | Differential Pressure Gage, Range 0-6 mm w.c., minor divisions .20, calibrated for vertical scale position. |
G2000-750PA | Differential Pressure Gage, Range 0-750 Pa, minor divisions 25.0. |
G2000-80CM | Differential Pressure Gage, Range 0-80 cm w.c., minor divisions 2.0. |
G2000-80MM | Differential Pressure Gage, Range 0-80 mm w.c., minor divisions 2.0. |
G2000-8KPA | Differential Pressure Gage, Range 0-8 kPa, minor divisions .20. |
G2001 | Differential Pressure Gage, Range 0-1.0″ w.c., minor divisions .02. |
G2001-SP | Differential Pressure Gage, Range 0-1″ w.c., with set point indicator. |
G2001AV | Differential Pressure Gage, Range 0-1.0″ w.c., velocity 500-4000 FPM. |
G2001D | Differential Pressure Gage, Range 0-1.0″ w.c. & 0-250 Pa. |
G2002 | Differential Pressure Gage, Range 0-2.0″ w.c., minor divisions .05. |
G2002-SP | Differential Pressure Gage, Range 0-2″ w.c., with set point indicator. |
G2002AV | Differential Pressure Gage, Range 0-2.0″ w.c., velocity 1000-5600 FPM. |
G2002D | Differential Pressure Gage, Range 0-2.0″ w.c. & 0-500 Pa. |
G2003 | Differential Pressure Gage, Range 0-3.0″ w.c., minor divisions .10. |
G2003D | Differential Pressure Gage, Range 0-3.0″ w.c. & 0-750 Pa. |
G2004 | Differential Pressure Gage, Range 0-4.0″ w.c., minor divisions .10. |
G2004D | Differential Pressure Gage, Range 0-4.0″ w.c. & 0-1.0 kPa. |
G2005 | Differential Pressure Gage, Range 0-5.0″ w.c., minor divisions .10. |
G2005-SP | Differential Pressure Gage, Range 0-5″ w.c., with set point indicator. |
G2006 | Differential Pressure Gage, Range 0-6.0″ w.c., minor divisions .20. |
G2006D | Differential Pressure Gage, Range 0-6.0″ w.c. & 0-1.5 kPa. |
G2008 | Differential Pressure Gage, Range 0-8.0″ w.c., minor divisions .20. |
G2008D | Differential Pressure Gage, Range 0-8.0″ w.c. & 0-2.0 kPa. |
G2010 | Differential Pressure Gage, Range 0-10″ w.c., minor divisions .20. |
G2010-SP | Differential Pressure Gage, Range 0-10″ w.c., with set point indicator. |
G2010AV | Differential Pressure Gage, Range 0-10″ w.c., velocity 2000-12500 FPM. |
G2010D | Differential Pressure Gage, Range 0-10″ w.c. & 0-2.5 kPa. |
G2015 | Differential Pressure Gage, Range 0-15″ w.c., minor divisions .50. |
G2015D | Differential Pressure Gage, Range 0-15″ w.c. & 0-3.7 kPa. |
G2020 | Differential Pressure Gage, Range 0-20″ w.c., minor divisions .50. |
G2025 | Differential Pressure Gage, Range 0-25″ w.c., minor divisions .50. |
G2030 | Differential Pressure Gage, Range 0-30″ w.c., minor divisions 1.0. |
G2040 | Differential Pressure Gage, Range 0-40″ w.c., minor divisions 1.0. |
G2050 | Differential Pressure Gage, Range 0-50″ w.c., minor divisions 1.0. |
G2060 | Differential Pressure Gage, Range 0-60″ w.c., minor divisions 2.0. |
G2080 | Differential Pressure Gage, Range 0-80″ w.c., minor divisions 2.0. |
G2100 | Differential Pressure Gage, Range 0-100″ w.c., minor divisions 2.0. |
G2150 | Differential Pressure Gage, Range 0-150″ w.c., minor divisions 5.0. |
G2201 | Differential Pressure Gage, Range 0-1 psi, minor divisions .02. |
G2202 | Differential Pressure Gage, Range 0-2 psi, minor divisions .05. |
G2203 | Differential Pressure Gage, Range 0-3 psi, minor divisions .10. |
G2204 | Differential Pressure Gage, Range 0-4 psi, minor divisions .10. |
G2205 | Differential Pressure Gage, Range 0-5 psi, minor divisions .10. |
G2210 | Differential Pressure Gage, Range 0-10 psi, minor divisions .20, MP option standard. |
G2215 | Differential Pressure Gage, Range 0-15 psi, minor divisions .50, MP option standard. |
G2220 | Differential Pressure Gage, Range 0-20 psi, minor divisions .50, MP option standard. |
G2230 | Differential Pressure Gage, Range 0-30 psi, minor divisions 1.0, HP option standard. |
G2300-0 | Differential Pressure Gage, Range 0.25-0-0.25″ w.c., minor divisions .01, calibrated for vertical scale position. |
G2300-100PA | Differential Pressure Gage, Range 50-0-50 Pa, minor divisions 2.0, calibrated for vertical scale position. |
G2300-10CM | Differential Pressure Gage, Range 5-0-5 cm w.c., minor divisions .20. |
G2300-120PA | Differential Pressure Gage, Range 60-0-60 Pa, minor divisions 2.0. |
G2300-1KPA | Differential Pressure Gage, Range 0.5-0-0.5 kPa, minor divisions .02. |
G2300-20MM | Differential Pressure Gage, Range 10-0-10 mm w.c., minor divisions .50, calibrated for vertical scale position. |
G2300-250PA | Differential Pressure Gage, Range 125-0-125 Pa, minor divisions 5.0. |
G2300-30CM | Differential Pressure Gage, Range 15-0-15 cm w.c., minor divisions 1.0. |
G2300-3KPA | Differential Pressure Gage, Range 1.5-0-1.5 kPa, minor divisions .10. |
G2300-4CM | Differential Pressure Gage, Range 2-0-2 cm w.c., minor divisions .10. |
G2300-500PA | Differential Pressure Gage, Range 250-0-250 Pa, minor divisions 10.0. |
G2300-60PA | Differential Pressure Gage, Range 30-0-30 Pa, minor divisions 1.0, calibrated for vertical scale position. |
G2301 | Differential Pressure Gage, Range 0.5-0-0.5″ w.c., minor divisions .02. |
G2302 | Differential Pressure Gage, Range 1-0-1″ w.c., minor divisions .05. |
G2304 | Differential Pressure Gage, Range 2-0-2″ w.c., minor divisions .10. |
G2310 | Differential Pressure Gage, Range 5-0-5″ w.c., minor divisions .20. |
G2320 | Differential Pressure Gage, Range 10-0-10″ w.c., minor divisions .50. |
G2330 | Differential Pressure Gage, Range 15-0-15″ w.c., minor divisions 1.0. |